- The PR5437 HART Temperature Transmitter offers high accuracy, flexibility, and ample configurability.
- This PR 5437A temperature transmitter has full SIL assessment and the 5437D additionally offers mounting in hazardous areas.
- The 5437 Series offers an improvement of traceability, better visibility of process variations, and enables proactive maintenance or process adjustment.
The PR 5437 HART Temperature Transmitter, setting the new standard for head mounted transmitters.
Redefining the Head Mount (Hockey Puck) Temperature Transmitter Industry
- highly accurate
- incredibly Stable
- very flexible
- extremely fast
- lots of approval options
- full SIL assessment
Superior Specification – PR 5437 HART Temperature Transmitter
Ultimate Performance
The PR 5437 HART Temperature Transmitter ensures maximum performance to satisfy the most demanding applications.
- general accuracy of ±0.05% of span
- response time of 70 ms
- wide ambient temperature range: -50o to 85o˚C
- temperature coefficient of ±0.005% of span / o˚C
- full assessment to SIL2/3 hardware and software for easy integration into safety instrumented systems
- linearization: Callender Van Dusen
- custom : spline, table, polynomial
True Dual Sensor Input – No Compromise on Sensor Type
With a unique, high density 7 terminal design, the 5437 is capable of accepting up to 2 x 4 wire RTD inputs. For example, the PR 5337 only accepts 2 x 2 wire inputs RTD, TC, and mV.
Advantages
- no compromise on sensor for highest accuracy applications
- wider range of applications
- e.g. WikaT32 and Rosemount 644 only 2 x 3W
Dual sensor functions include:
- redundancy
- differential
- average
- minimum / maximum tracking
Sensor Redundancy
Improving Process Uptime and Availability
The new PR 5437 HART Temperature Transmitter includes a sensor redundancy function to reduce potential downtime due to sensor errors.
Advantages
- seamless switch to backup sensor in case of failure
- NE107 compliant alert via HART allowing maintenance scheduling on faulty sensor
- maintains process, preventing downtime and potential loss of production or yield
- avoids potential safety or environmental issues in the event of a sensor failure
Sensor Drift Detection
Maintaining Process Accuracy
The PR 5437 HART Temperature Transmitter includes a sensor drift detection function to ensure accuracy and integrity of process values.
Advantages
- user specifies acceptable sensor drift limits
- NE107 compliant alert via HART and/or user can select analog output error and to alert for scheduling maintenance
- prevents inaccurate values from influencing the process, which could potentially affect yields or production quality
Process Optimization and Reporting via PR 5437 HART Temperature Transmitter
Improving Process Control and Visibility
Dynamic variable mapping and runtime metering, together with programmable sensor limits, offer tight process control, an improvement of safety, and traceability
Advantages
- minimum / maximum tracking records process extremes
- metering of ambient operating temperatures
- sensor average measurements
- improve scheduling of maintenance, save costs
- process optimization through improving statistical data availability
Programmable Sensor Limits
Improved Process Control and Visibility
The programmable sensor limits enable out of range sensor inputs and outputs for identification and action.
Advantages
- signals out of range inputs, sensor, or process runaway
- can identify if process material has exposure to over-temperatures
Specification Comparison vs Competitors
Competitor Comparison
Advantages
- best in class specification
Runtime Metering with this HART Temperature Transmitter
Improving Traceability
Both electronics and sensor temperatures are metered including time spent in user defined ranges and tracking of minimum and maximum temperatures.
Advantages
- ensures better process traceability
- improves visibility of process variations
- enables proactive maintenance or process adjustment
Diagnostics: NE107
Self Monitoring and Diagnosis of Field Devices
The PR 5437 HART Temperature Transmitter is NE107 compliant, which allows users to take advantage of standard error reporting and diagnostics.
Design Optimization of the PR 5437 HART Temperature Transmitter
The PR 5437 optimizes design for ease of installation and troubleshooting.
- ¼” center hole to accommodate wide selection of sensor / probe diameters e.g. spring loaded
- possibility to wire the transmitter from either the outside or inside of the captive screw terminals
- dual color status LED to NE44 (heartbeat, sensor, and functional errors)
- 4-20 mA test pins for loop current inspection
- hardware (jumper) setting of write protect and transmitter burnout
Future-Proof Concept
In order for the PR 5437 to take advantage of emerging technologies, it includes an expansion port for potential future peripherals and connectivity.
Configuration Options
- PC with Looplink
- PC with HART modem
- hand held communicator
- DCS / PLC field device management