Search
Close this search box.
(281) 491-3833
process-solutions-corp-industrial-instrumentation-distributor-logo

CS80 Intrinsically Safe Pressure Transducer, 50-30,000 PSI

CS80 Intrinsically Safe Pressure Transducer, 50-30,000 PSI

The CS80 Intrinsically Safe Pressure Transducer is an industrial quality sensor for use in Class I, Division 1 intrinsically safe areas. This hazardous area pressure sensors offers a wide range of configurable options, making it a versatile pressure transducer that is suitable for operation in many harsh conditions. Additionally, the CS80, from Core Sensors, features an all welded stainless steel construction for a minimum IP65 rating.

Description

The CS80 Intrinsically Safe Pressure Transducer is a high strength sensor for use in Class I, Division 1 intrinsically safe areas. The CS80 features an all welded stainless steel construction for a minimum IP65 rating. A wide range of configurable options make the CS80, from Core Sensors, a versatile pressure transducer that can operate in some the harshest conditions.

Low power outputs are available which can operate off of 3-5 VDC of unregulated power to extend battery life in remote applications. The CS80 is an excellent solution for applications such as natural gas compression and oil exploration. Caution must be taken when installing and operating hazardous area pressure sensors in known Class I, Division 1 locations. Please review the Intrinsically Safe Operating Instructions prior to installation.

  • plug and play installation
  • CSA Class I, Division 1, Groups C, D T4 approval
  • pressures from 50 to 30,000 PSI
  • see model CS81 for pressures below 50 PSI
  • one piece design
  • assembly in New Jersey, USA

CS80 Intrinsically Safe Pressure Transducer

We offer a variety of high quality accessories to bundle with the CS80 Intrinsically Safe Pressure Transducer to simplify installation. Common accessories include:

  • mating cordsets
  • field wireable mating connectors
  • cooling adapters

Specifications

Performance Thermal Environmental

Accuracy @ 77˚F (25˚C)1

  • ≤ ±0.25% BFSL
  • ≤ ±0.5% BFSL (> 10,000 PSI)
  • ≤ ±1% BFSL (Millivolt output signal)

Stability (1 Year)

  • ≤ ±0.25% of FS

Pressure Cycles

  • 100 million

Overpressure

  • 2X minimum

Burst Pressure

  • 5X or 60,000 PSI, whichever is less

Operating Temperature

  • -40 to 176˚F
  • -40 to 80˚C

Operating Temperature
(Electrical connection “F”, DIN 43650-A)

  • -4 to 176˚F
  • -20 to 80˚C

Media Temperature

  • -40 to 257˚F
  • -40 to 125˚C

Media Temperature
(Electrical connection “F”, DIN 43650-A)

  • -40 to 221˚F
  • -40 to 105˚C

Compensated Temperature

  • 32 to 131˚F
  • 0 to 55˚C

Storage Temperature

  • -40 to 257˚F
  • -40 to 125˚C

TC Zero

  • ≤ ±1% of FS

TC Span

  • ≤ ±1% of FS

EMI/RFI Protection

  • Yes

IP Rating2

  • IP65 minimum

Vibration

  • 10 g, 20 to 2000 Hz

Shock

  • 100 g, 11 msec, 1/2 sine
1Accuracy includes non-linearity, hysteresis and non-repeatability.
2IP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.

Electrical Specifications

Current Voltage Ratiometric Low Power Millivolt

Outputs

  • 4-20 mA

Excitation

  • 10-28 VDC

Current Consumption

  • 20 mA, typical

Output Load

  • 0-800 Ohms @ 10-28 VDC

Frequency Response (min)

  • ~250 Hz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 1-5 V
  • 1-6 V

Excitation

  • 10-28 VDC

Current Consumption

  • < 10 mA

Output Load

  • 5 K Ohms, min

Frequency Response (min)

  • ~1 kHz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 0.5-4.5 V ratiometric

Excitation

  • 5 VDC ±0.5V

Current Consumption

  • < 10 mA

Output Load

  • 5 K Ohms, min

Frequency Response (min)

  • ~1 kHz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 0.5-2.5 V non-ratiometric

Excitation

  • 3-5 VDC unregulated

Current Consumption

  • ≤ 3 mA

Output Load

  • 5 K Ohms, min

Frequency Response (min)

  • ~1 kHz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 10 mV/V

Excitation

  • 5 VDC, typical

Current Consumption

  • < 5 mA

Output Load

  • > 1 M Ohms

Frequency Response (min)

  • ~5 kHz

Zero Offset (of FS)

  • ≤ ±2%

Span Tolerance (of FS)

  • ≤ ±2%

Model Configuration Guide for the CS80 Intrinsically Safe Pressure Transducer

CS80-Intrinsically-Safe-Pressure-Transducer-Core-Sensors-Process-Solutions-Texas

Approvals and Certifications

NOTE: Users must use an approved barrier to maintain listed certifications. See page 4 of the data sheet for entity parameters.

Common Uses of the CS80 I.S. Pressure Sensor

industrial-pressure-transducers-core-sensors-quality-pressure-transmitter-process-solutions-corp

Need a Quote?

Let us know and we will contact you shortly.