The PR 6437D, from PR electronics, is an intrinsically safe, programmable temperature transmitter that uses HART  7 protocol and features multiple hazardous area approvals. It features programmable input limits with runtime metering to ensure maximum process traceability and sensor out of range protection.

  • RTD, thermocouple (TC), potentiometer, linear resistance, and bipolar mV input
  • single or true dual inputs with sensor redundancy and drift detection
  • can be mounted in zone 0, 1, 2 and zone 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D

Description

The PR 6437D, from PR electronics, is an intrinsically safe, HART 7 temperature transmitter with multiple hazardous area approvals. It features programmable input limits with runtime metering to ensure maximum process traceability and sensor out of range protection.

  • RTD, thermocouple (TC), potentiometer, linear resistance, and bipolar mV input
  • wide ambient operating temperature of -50 to 85°C (-58 to 185˚F)
  • total accuracy from 0.014% 2.5 kVAC galvanic isolation
  • full assessment to IEC61508 : 2010 for use in SIL 2/3 applications

Features of this Industrial Temperature Transmitter

  • True Dual Input Transmitter – accepts the widest range of dual input combinations
  • Sensor Redundancy – output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime
  • Sensor Drift Detection – alerts when sensor differential exceeds user-defined limits, for maintenance optimization
  • Dynamic Variable Mapping for process data in addition to the primary variable e.g. dual input features such as average, differential and minimum / maximum tracking
  • Digital and Analog Signal – groundbreaking accuracy over full input span and ambient conditions
  • Extensive Sensor Matching including Callendar Van Dusen and custom linearization
  • Programmable Input Limits with runtime metering ensure maximum process traceability and sensor out of range protection
  • IEC 61508 : 2010 – full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1
  • NAMUR Compliant – meets NE21, NE43, NE44, NE89 and NE107 compliant diagnostics information
  • available in models that are suitable for the use in systems up to Performance Level “d” according to ISO-13849

Easy, Flexible Mounting

  • DIN rail mounting with up to 84 inputs per meter
  • configuration via PReset software using PR5909 Loop Link / HART modem, or by asset management tool (e.g. Pactware, AMS, HART communicator)
  • the 6437D can be mounted in zone 0, 1, 2 and zone 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D

Common Uses of the 6437D Temperature Transmitter from PR electronics

  • temperature measurement of a wide range of TC and RTD types
  • conversion of wide span linear resistance and potentiometer inputs to 4-20 mA
  • conversion of bipolar mV signals to 4-20 mA
  • integration into asset management schemes
  • critical applications requiring superior accuracy and/or sensor redundancy and drift detection