Kayden CLASSIC 800 Series, Switch and Transmitter
Kayden CLASSIC 800 Series, Switch and Transmitter
The CLASSIC 800 Series switch and transmitter offers threaded, flanged, Tri-Clamp, and retractable packing gland process connection. It is user configurable for flow, level, fluids interface, temperature applications, and is suitable for use in air, gases, water, liquids, and slurries. Models in the Kayden CLASSIC 800 Series have several unique features that make them the world’s most advanced thermal flow and level switch including: temperature mode, 4-20 mA outputs, Modbus, digital temperature compensation, automated self-test diagnostics, and a simple, intuitive user interface.
The patented design of the CLASSIC 800 Series provides the ultimate performance and features package for flow, level, interface, and temperature sensing. It combines precision welded, highly accurate sensors, extremely rugged enclosures, and advanced digital electronics. In addition, these switches / transmitters offer failure resistance inherent in Thermal Dispersion technology with the performance and features usually reserved for much more expensive instrumentation.
- digital microprocessor technology
- settings configurable by user for flow, level, interface, and temperature sensing
- no jumpers – all configurable options are stored in non-volatile memory
- hazardous area, explosion proof, and ip rating options available
Description
The CLASSIC 800 Series features switches and transmitters for flow, level, interface, and temperature process control. Each model has a precision welded, highly accurate stainless steel thermal sensor. The Kayden CLASSIC 800 Series is ideal for liquids, gases, and slurries in clean or dirty processes. Options for process connections include: raised face, RTJ flange, threaded, or retractable packing glands. In addition, all Kayden CLASSIC models feature a rugged flameproof enclosure with blind or lens cover options. Its advanced digital electronics will revolutionize the way you monitor and control your process.
- easy setup; no jumpers or trim pots
- continuous self-test diagnostics with fault indicator
- temperature compensation
- universal power 12-24 VDC and 115-230 VAC standard
- two SPDT relays – independently adjustable
- 4-20 mA analog output
- smart heater function for power economy and increased heater life
- start-up bypass timer (for pump control)
Kayden CLASSIC 800 Series Model Line Up
Kayden CLASSIC 810 – Threaded
Process Connections – MNPT
- 1/2 inch, 3/4 inch, 1.0 inches, 1 1/4 inches, 1 1/2 inches, 2 inches
Approvals
- FM
- CSA
- CRN
- Single Seal
- NACE
- ASME BPVC Sec. VIII Div. 1
Kayden CLASSIC 812 – Flanged
Process Connection
- raised face, RTJ flange
Approvals
- FM
- CSA
- CRN
- Single Seal
- NACE
- NEMA 4X
Kayden CLASSIC 814 – Flanged Retractable Packing Gland
Process Connection
- retractable packing gland, raised face, or RTJ flange
Approvals
- CSA
- FM
- Single Seal
- NACE
- NEMA 4X
Kayden CLASSIC 816 – Threaded Retractable Packing Gland
Process Connection
- threaded retractable packing gland (1″ MNPT)
Approvals
- CSA
- Single Seal
- NACE
- NEMA 4X
Kayden CLASSIC 830 – In-Line Threaded
Process Connection
- 3/4″ FNPT
Approvals
- CSA
- Single Seal
- NACE
- NEMA 4X
Kayden CLASSIC 832 – In-Line Flanged
Process Connections
- raised face, RTJ flange
Approvals
- FM
- CSA
- Single Seal
- NACE
- NEMA 4X
Configuration Options for the Kayden CLASSIC 800 Series*
*options vary by model selection
Applications for the Kayden CLASSIC 800 Series
- flow
- level
- interface
- temperature
Process Connections
- 3/4″ FNPT
- flanged in-line
- MNPT
- 1/2 inch
- 3/4 inch
- 1 inch
- 1-1/4 inches
- 1-1/2 inches
- 2 inches
- 1 to 3.5 inches Tri-Clamp
- flanged
- sanitary
- retractable packing glands
- threaded (1” MNPT)
- flanged
Sanitary Tri-Clamp Style
Maximum Working Pressure
- per flange rating
Flanged Style
Maximum Working Pressure
- per flange rating
Insertion ‘U’ Lengths
Standard
- 1.2 inches (3 cm)
- 2 inches (5 cm)
- 3 inches (7.5 cm)
- 4 inches (10 cm)
- 6 inches (15 cm)
- 9 inches (23 cm)
- 12 inches (30 cm)
- 18 inches (45 cm)
Kayden CLASSIC 828 (Sanitary)
- 2 inches (5 cm)
- 3 inches (7.5 cm)
- 4 inches (10 cm)
- 6 inches (15 cm)
Custom Lengths
- custom lengths available by 1/2″ (1 cm) increments
- Kayden CLASSIC model dependent: minimum 1.2 inches (3 cm) to maximum 120 inches (305 cm)
Input Power Options
Universal Power Standard
- 12-24 VDC
- 115-230 VAC
- 50-60 Hz
Consumption
- maximum: 6.0 watts (fully configured)
Outputs
- 4-20 mA current loop
- two (2) independent SPDT sealed relay contacts
- rated at 4 amps resistive 230 VAC or 30 VDC maximum
- individually adjustable
Accuracy
Flow Service
- ±1% set point velocity over operating range of ±50˚F (±28˚C)
Level Service
- ±0.25 inches (±0.64 cm)
Response Time
- approximately 0.5 to 30 seconds
Remote Electronics Options
Maximum Recommended Cable Length
- 200 feet (60 meters)
Cable Type
- 24 AWG minimum
- twisted pairs
Heater Power
- field adjustable to optimize performance
Start Up Bypass Timer
- adjustable for 0 to 100 seconds
Communications
- Modbus via RS-485
Operating Pressure (Maximum)
Maximum Working Pressure
- 24 MPa (3500 psig) dependent on Kayden CLASSIC model and material of construction
Temperature Range (Sensor)
Continuous Service
- -50 to 392˚F (-45 to 200˚C)
- -40 to 320˚F (-40 to 160˚C) [Kayden CLASSIC 814 and Kayden CLASSIC 816]
Electronics
- -67˚F to 149˚F (-55˚C to 65˚C)
Note: For temperatures above 149˚F (65˚C), electronics must be remotely mounted.
Storage
- All Kayden CLASSIC models should be stored in a clean and dry environment between -34.5 to 140˚F (-30 to 60˚C).
Enclosure Material
- copper-free aluminum (does not exceed 0.4% copper)
- powder coated polyester TGIC (polyester triglycidyl isocyanurate)
- NEMA 4 / Type 4 / IP55 rated
- 1” FNPT conduit connection
- buna o-ring on cover
Conduit Connection Cover
- flameproof: blind cover or glass lens
Wetted Materials
- 316/316L stainless steel – standard
- titanium grade 2
- Hastelloy C-276
- 316/316L stainless steel with nickel braze [Kayden CLASSIC 830 and Kayden CLASSIC 832 only]
- highly saturated nitrile (pressure seal) [Kayden CLASSIC 814 and Kayden CLASSIC 816 only]
- other wetted material options available
Outputs and Communications for the Kayden CLASSIC 800 Series
- two independent relays (SPDT)
- 4-20 mA
- Modbus
- rated:
- 120 Vac max
- 30 Vdc max
- 4A max
Switch Point Range, Insertion Style
Water-based Liquids
- 0.01 to 3.0 feet/second (0.003 to 0.9 meters/second)
Hydrocarbon-based Liquids
- 0.01 to 5.0 feet/second (0.003 to 1.5 meters/second)
Gases
- 0.25 to 254 sfps (0.076 to 77 smps)
- standard conditions: 70˚F (21˚C) at 14.7 psi (1 atm)
Switch Point Range, In-Line Models
Water-based Liquids
- 0.015 to 50 cc/second
Hydrocarbon-based Liquids
- 0.033 to 110 cc/second
Gases
- 0.6 to 20,000 cc/second
- standard conditions: 70˚F (21˚C ) at 14.7 psi (1 atm)
RCMS (Remote Control & Monitoring Software) Functions and Features
- display panel lock-out
- set points configuration*
- relay actuation delay timer
- independently configurable for both on and off / increasing or decreasing
- adjustable from 0 to 5,000 seconds
- start-up bypass timer*
- adjustable from 0 to 100 seconds
- relay mode configuration*
- energized above or below set point
- relay temperature mode configuration
- heater power setting*
- zero and span settings*
- analog (4-20 mA) output configuration*
- view and print graphing (trend) function
- configuring settings; write to device, save to file, and print
- fault event log
*also configurable from display panel
Weights and Dimensions
- 810 threaded: 2″ ‘U’ length: 7 pounds (3.18 kg)
- carton size: 15x5x6 inches (38x13x15 cm)
- other models/sizes: contact us for more information
Warranty
- one (1) year from shipment date from factory (see full Terms and Conditions for details)
Display Panel Indicators
- relay 1 and 2
- set point 1 and 2
- fault alarm
- run mode
- start-up bypass timer (for pump control)
- LED bar graph for flow rate, level, or interface indication
Configuration Mode Features
- adjustable sensitivity
- zero and span adjustment
- Modbus addressable
Diagnostics
- primary watchdog circuit monitors microprocessor parameter anomalies
- secondary watchdog circuit monitors microprocessor health
- heater monitored for out-of-range conditions
- fault mode de-energizes relay(s) and halts power to the heater
Approvals and Certifications
- ANSI/UL Class I, Div. 1, Groups B, C and D
- Ex d IIB + H2
- AEx d IIB+H2 (Class I, Zone 1, Group IIB + H2,) T3
- Enclosure Type 4 / IP55 rated
Single Seal Approval
- Per ANSI/ISA 12.27.01-2003
- Class I, Div. 1, Groups B, C and D
- Class I, Zone 1, AEx d IIB+H2 T2D (Ta=75˚C) / T3 (Ta=65˚C)
- Enclosure Type 4 / IP55 rated
CRN Canadian Registration Number
- CRN approvals available
- contact us for CRN information per model and jurisdiction
Applications for the Kayden CLASSIC 800 Series
Flow
- flow switch for pump protection – dry alarm
- leak detection
- flow monitoring and verification
- tank overflow protection
- flare gas monitoring
- monitoring purge air flow
- lube oil systems
- vent monitoring
- natural gas to boilers
- emergency eye wash and shower stations
- drain line flow
- high pressure flows
- tanker loading and unloading
- relief valve and rupture disk flow monitoring
- remote indication of flow via analog and digital output communications
- chemical injection / additive flow monitoring
Level
- storage tanks
- oil separators and treaters – high, low, & interface level
- sumps – all types of fluids ( water, oil, etc. )
- free water knock-out tanks – high, low, and interface level
- leak detection (accumulation reservoir)
- tank overflow
- sampler systems
- sand separators
Interface
- control in separation vessels
- detection
- control and level detection in settling vessels
Media
- liquids, air, and gases
- hazardous area and general-purpose areas
- slurries
- corrosive liquids
Process Conditions for this Switch / Transmitter for Flow, Level, Interface, and Temperature
Flow | |
---|---|
Ideal Process Conditions | Undesirable Process Conditions |
Liquids
Air & Gas
Slurries
Emulsion
|
Liquids
Air & Gas
Slurries
Emulsion
Solids
|
Level | |
Ideal Process Conditions | Undesirable Process Conditions |
Liquids
Slurries
Emulsion
|
Liquids
Slurries
Emulsion
Solids
|
Interface | |
Ideal Process Conditions | Undesirable Process Conditions |
Liquid to Liquid
Air or Gas to Liquid
Emulsion
|
Liquid to Liquid
Air or Gas to Liquid
Emulsion
Solids
|
Product Documents
- Data Sheet - Kayden CLASSIC 800 Series
- Brochure - Kayden CLASSIC 800 Series
- Quick Set Up Guide - Kayden CLASSIC 800 Series
- Product Manual - Kayden CLASSIC 800 Series
- Quick Reference Guide - Flow to Velocity
- Modbus Protocol Register Declarations
- Process Conditions Considerations
- Wiring Diagram - Integral Electronics
- Wiring Diagram - Remote Electronics
- Certificates and Approvals - CSA 2015
- Certificates and Approvals - FM 2005