M-Th: 8AM-5PM

Fri: 7:30AM-3PM

M-Th: 8AM-5PM

Fri: 7:30AM-3PM

CS81 Intrinsically Safe Low Pressure Transducer, 1-49 PSI

CS81 Intrinsically Safe Low Pressure Transducer, 1-49 PSI

The CS81 Intrinsically Safe Low Pressure Transducer is an industrial quality sensor for low pressure measurements in intrinsically safe hazardous locations. This pressure sensor features an all welded stainless steel construction, which allows it to offer a minimum IP65 rating. With a wide range of configurable options, the CS81 from Core Sensors, is a versatile pressure transducer that can operate in extreme conditions.

  • pressures from 1 to 49 PSI
  • media isolated
  • wide variety of configurations available
  • IP65 minimum rated
  • approvals and certifications: CSA Class I, Division 1 Groups C,D T4; Class I, Zone 0 AEx ia IIB T4 Ga (Ex ia IIB T4 Ga); ABS; CE

Description

The CS81 Intrinsically Safe Low Pressure Transducer is a high strength sensor for low pressure measurements in intrinsically safe areas. The CS81 features an all welded stainless steel construction for a minimum IP65 rating. A wide range of configurable options makes the CS81, from Core Sensors, a versatile pressure transducer that can operate in some of the harshest conditions.

Low power outputs are available which can operate off of 3-5 VDC of unregulated power to extend battery life in remote applications. The CS81 is an excellent solution for applications such as external fuel tank monitoring, vapor recovery, and natural gas compression. Caution must be taken when installing and operating hazardous area instrumentation in known Class I, Division 1 locations. Please review the Intrinsically Safe Operating Instructions prior to installation.

  • plug and play installation
  • CSA Class I, Division 1, Groups C, D T4 approval
  • pressures from 1 to 49 PSI, see model CS80 for pressures 50 PSI and above
  • media isolated
  • assembly in New Jersey, USA

CS81 Intrinsically Safe Low Pressure Transducer

We offer a variety of high quality accessories to bundle with the CS81 Intrinsically Safe Low Pressure Transducer to simplify installation. Common accessories include:

  • mating cordsets
  • field wireable mating connectors
  • cooling adapters

Specifications for the CS81 Low Pressure Transducer

Performance Thermal Environmental

Accuracy @ 77˚F (25˚C)1

  • ≤ ±0.25% BFSL
  • ≤ ±0.5% BFSL (2 PSI & below)
  • ≤ ±1% BFSL (Millivolt output signal)

Stability (1 Year)

  • ≤ ±0.25% of FS

Pressure Cycles

  • 100 million

Overpressure

  • 2X minimum

Burst Pressure

  • 5X or 245 PSI, whichever is less

Operating Temperature

  • -40 to 176˚F
  • -40 to 80˚C

Operating Temperature
(Electrical connection “F”, DIN 43650-A)

  • -4 to 176˚F
  • -20 to 80˚C

Media Temperature

  • -40 to 257˚F
  • -40 to 125˚C

Media Temperature
(Electrical connection “F”, DIN 43650-A)

  • -40 to 221˚F
  • -40 to 105˚C

Compensated Temperature

  • 32 to 131˚F
  • 0 to 55˚C

Storage Temperature

  • -40 to 257˚F
  • -40 to 125˚C

TC Zero

  • ≤ ±1% of FS
  • ≤ ±2% of FS (2 PSI & below)

TC Span

  • ≤ ±1% of FS
  • ≤ ±2% of FS (2 PSI & below)

EMI/RFI Protection

  • Yes

IP Rating*

  • IP65 minimum

Vibration

  • 10 g, 20 to 2000 Hz

Shock

  • 100 g, 11 msec, 1/2 sine
1Accuracy includes non-linearity, hysteresis and non-repeatability.
2IP Rating is dependent on electrical termination selected. Contact us for more information. IP Rating applies when electrical connector is attached with the appropriate ingress protection.

Electrical Specifications

Current Voltage Ratiometric Low Pressure Millivolt

Outputs

  • 4-20 mA

Excitation

  • 10-28 VDC

Current Consumption

  • 20 mA, typical

Output Load

  • 0-800 Ohms @ 10-28 VDC

Frequency Response (min)

  • ~250 Hz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 1-5 V
  • 1-6 V

Excitation

  • 10-28 VDC

Current Consumption

  • < 10 mA

Output Load

  • 5 K Ohms, min

Frequency Response (min)

  • ~1 kHz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 0.5-4.5 V ratiometric

Excitation

  • 5 VDC ±0.5 V

Current Consumption

  • < 10 mA

Output Load

  • 5 K Ohms, min

Frequency Response (min)

  • ~1 kHz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 0.5-2.5 V non-ratiometric

Excitation

  • 3-5 VDC unregulated

Current Consumption

  • ≤ 3 mA

Output Load

  • 5 K Ohms, min

Frequency Response (min)

  • ~1 kHz

Zero Offset (of FS)

  • ≤ ±0.5% typical, ±1% max

Span Tolerance (of FS)

  • ≤ ±0.5% typical, ±1% max

Outputs

  • 10 mV/V

Excitation

  • 5 VDC, typical

Current Consumption

  • < 5 mA

Output Load

  • > 1 M Ohms

Frequency Response (min)

  • ~5 kHz

Zero Offset (of FS)

  • ≤ ±2%

Span Tolerance (of FS)

  • ≤ ±2%

Model Configuration Guide

CS81-Intrinsically-Safe-Low-Pressure-Transducer-Core-Sensors-Process-Solutions-Corp-Configurations

Approvals and Certifications

NOTE: Users must use an approved barrier to maintain listed certifications. See page 4 of the data sheet for entity parameters.

Common Uses of the CS81

industrial-pressure-transducers-core-sensors-quality-pressure-transmitter-process-solutions-corp

Need a Quote?

Let us know and we will contact you shortly.