M-Th: 8AM-5PM

Fri: 7:30AM-3PM

M-Th: 8AM-5PM

Fri: 7:30AM-3PM

XL15 Prime: HMI, PLC, and I/O All-in-One Automation Controller

XL15 Prime: HMI, PLC, and I/O All-in-One Automation Controller

The XL15 Prime has an all-new design that has narrower bezels and a 14% smaller footprint overall. This automation controller is also one of the first Horner Automation products to utilize USB Type C. With a more advanced processor and modern memory architecture, users can enjoy XL Prime Series levels of performance increase and 100% non-volatile memory with just a coin cell battery for its real time clock.

Description

The XL15 Prime features a logic engine with 2MB of application memory and a 0.02 mS/K logic scan. With its Online Programming Mode, this automation controller allows users to make logic changes on the fly without going through stop mode.

Operator Interface Features of the XL15 Prime Automation Controller

  • 1024×768 LCD TFT color graphics display with a high resolution resistive touchscreen
  • 7 virtual function keys and system key
  • programming available via USB-C
  • USB 2.0 Host port (A) is available for exchanging files with
  • USB FLASH drives
  • two (2) RS-232 / RS-485 ports to support RTU / Modbus Commander / Responder (Master / Slave), ASCII In / Out, and PLC / Drive downloadable protocols

Networking Features

  • two (2) built-in 10/100 Ethernet port
  • two (2) integrated CAN ports that support CsCAN and either CANopen, SAE J1939, or DeviceNet Scanner simultaneously
  • all units feature a microSD slot, supporting at least 32GB
  1. Virtual Function Keys (slide in from the right upon touching top right corner of screen)
  2. optional built-in I/O
  3. high capacity microSD slot
  4. USB C port
  5. CAN 1 port
  6. USB A port
  7. mic input / audio output
  8. dual ethernet LAN ports
  9. DIP switches
  10. power
  11. MJ 1/2
  12. MJ 3
  13. CAN 2 port
XL15-Prime-Automation-Controller-Overview-HMI-PLC-Controls-Process-Solutions-Corp

I/O Overview

The XL15 Prime is a compact automation controller that contains high density and very versatile I/O (input / output). Using the I/O properly requires wiring to the proper terminals, configuring jumpers inside the Horner OCS unit and configuring Cscape properly. The inputs are designed to support both positive and negative input modes. For many models, the mode is set by a jumper setting and a configuration parameter in Cscape. FurFurthermore, elay outputs are designed to switch loads that typically have high voltage or current requirements or require the isolation that relays provide.

XL15 Prime Automation Controller Model Line-Up

Model Configuration
HE-XP15E0 No built-in I/O
HE-XP15E2 12 DC in, 6 Relay Out, 4 – 12-bit Analog In
HE-XP15E3 12 DC in, 12 DC Out, 2 – 12-bit Analog In
HE-XP15E4 24 DC in, 16 DC Out, 2 – 12-bit Analog In
HE-XP15E5 12 DC in, 12 DC Out, 2 – 14/16-bit Analog In (mA/V/Tc/mV/RTD), 2 – 12-bit Analog Out
HE-XP15E6 12 DC in, 12 DC Out, 6 – 14/17-bit Analog In (mA/V/Tc/mV/RTD), 4 – 12-bit Analog Out