PR 5437A 2-wire HART Temperature Transmitter
Categories: Temperature Transmitters, Temperature Transmitters
Tags: HART, HazLoc rated, hockey puck (head mounted)
Brand:PR electronics
PR 5437A 2-wire HART Temperature Transmitter
- RTD, TC, potentiometer, linear resistance and bipolar mV input
- Single or true dual inputs with sensor redundancy and drift detection
- Wide ambient operating temperature of -50 to 85˚C
- Total accuracy from 0.014%
- 2.5 kVAC galvanic isolation
- Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications
Description
- RTD, TC, potentiometer, linear resistance, and bipolar mV input
- Single or true dual inputs with sensor redundancy and drift detection
- Wide ambient operating temperature of -50 to +85°C
- Total accuracy from 0.014%
- 2.5 kVAC galvanic isolation
- Full assessment to IEC61508: 2010 for use in SIL 2/3 applications
Common Applications for the PR 5437A HART Temperature Transmitter
- Temperature measurement of a wide range of TC and RTD types.
- Conversion of wide span linear resistance and potentiometer inputs.
- Conversion of bipolar mV signals to 4-20 mA.
- Integration into asset management schemes.
- Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.
Technical Characteristics of the PR 5437A
- True dual input transmitter. The high-density 7-terminal design accepts the widest range of dual input combinations.
- Sensor redundancy – output automatically switches to a secondary sensor in the event of primary sensor failure, maintaining uptime.
- Sensor drift detection – alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
- Dynamic variable mapping for process data in addition to the primary variable e.g. dual input features such as average, differential, and minimum / maximum tracking.
- Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
- Extensive sensor matching including Callendar Van Dusen and custom linearizations.
- Programmable input limits and runtime metering ensure maximum process traceability and sensor out of range protection.
- IEC 61508: 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
- The 5437A meets NAMUR NE21, NE43, NE44, NE89, NE95, and NE107 compliant diagnostics information.
Easy Mounting and Installation
- For DIN form B sensor head mounting.
- Configuration via standard HART communication interfaces or by PR 5909 Loop Link.
- The PR 5437A HART Temperature Transmitter can be mounted in zone 2 and 22 / Class I, Division 2, Groups A, B, C, D.
- The PR 5437D Ex HART Temperature Transmitter can be mounted in zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D.