Multipoint Flow Meter, Master-Touch Series 9000MP
Model the reliability of the Master‑Touch Series 9000MP from EPI. Built to withstand harsh industrial environments, this multipoint thermal mass flow meter delivers pinpoint accuracy and dependable real‑time data—ideal for large air intake ducts, flue stacks and other high‑volume gas systems. Upgrade your monitoring with unwavering performance.
- Designed for large cross‑section ducts and flue stacks, with multiple sensors and averaging for accurate gas flow measurement.
- Rugged construction: stainless steel hinge & screws, polyurethane foam gasket, corrosion‑resistant enclosure suitable for wet or harsh environments.
- Optional Air Purge System cleans the sensors automatically, preserving accuracy in particulate‑laden or dirty gas applications.
- High‑performance measurement: accuracy ±(1% reading + 0.5% full scale + GTC), repeatability ±0.2% full scale, NIST‑traceable calibration.
Product Documents
Description
For applications that require advanced multipoint measurements of thermal mass flow, the 9000MP Multipoint flow meter is the essential choice for you. This sensor flow enclosure on this multipoint flow meter system, from Eldridge Products Inc. (EPI) is highly durable and can be in service in wet, corrosive and high temperature environments.
- Stainless steel continuous hinge and stainless steel corner screws
- Maintenance free and corrosion resistant
- Gaskets are made from continuously poured polyurethane foam
- The remote enclosure is also durable and watertight
- Flat cover with bonded window
- Stainless steel continuous hinge as well as stainless steel corner screws
Able to effectively function in any large air intake ducts, air exhausts, or flue stacks, these dynamic and advanced flow meters deliver unparalleled service. Perfect for large industry settings and currently in use at many pulp and paper mills and also power source companies across the world, the Series 9000MP is the pinnacle of large-scale thermal mass flow insertion flow meters.
Multipoint Flow Meter, Master-Touch Series 9000MP
A unique feature of the 9000MP multipoint flow meters is that they can integrate an optional Air Purge System, which provides a simple way to clean the sensors. This feature is completely dynamic, giving you control over duration as well as frequency with EPI’s state-of-the-art Master-Touch Software.
- Perfect for large scale industry operations
- Multiple probe system for reliability
- Replaceable and removable sensors
- Constant and Trustworthy monitoring
Master-Touch products include a rugged, cleanable, thermal mass flow sensor. These units consist of a sensor assembly which utilizes two RTD (Resistance Temperature Detector) sensing elements. The sensors consist of reference grade platinum, ceramic, glass, and also stainless steel. Two platinum resistance sensors are built up upon the ceramic substrate and then given a thin glass coating. The assembly is then slipped into a stainless-steel sheath for corrosion and abrasion resistance. The sensor assembly is large, rugged, in addition to being relatively insensitive to dirt buildup.
During operation, the temperature sensor constantly measures the ambient temperature of the gas and maintains a reference resistance on one side of a bridge circuit. The temperature sensor and bridge circuitry forces the second sensor through self-heating to a constant temperature above that of the gas stream. The bridge maintains the overheat temperature and counterbalances the temperature effects through EPI’s proprietary temperature compensation techniques.
Master-Touch 9000MP Multigen Multiple Point Insertion Flow Meter
Master-Touch Multigen multiple point flow meters provide accurate, consistent, and rapid real-time flow measurement with a sensor that is both temperature and pressure corrective. Each flow meter offers calibration using standards traceable to the National Institute of Standards and Technology (NIST).
- Accuracy: ±(1% of reading + 0.5% of full scale + GTC)
- Repeatability: ±0.2% of full scale
- Sensor response time: 1 second to 63% of final value
- Gas temperature coefficient (GTC): 0.02% full scale/˚C
- Gas pressure effect: negligible over ±50% of factory calibration pressure
9000MP Multipoint Flow Meter for Gas Flows
Multipoint flow meter systems measure gas flows where two or more sensing points are necessary due to large cross-sectional areas, such as large air intake ducts, air exhaust, or flue stacks.
Master-Touch 9000MP Multipoint flow meter Systems are widely in use throughout the world, providing our customers with years of steady, reliable service. In combination with EPI’s new Air Purge System, Master-Touch 9000MP multiple point flow systems are ideal to an even greater variety of industrial applications. The probe design supports applications as diverse as ambient air flows in HVAC ducts, exhaust gas in large diameter stacks, boiler NOx efficiency systems, and municipal waste incinerators.
Our customers include global companies for example, environmental/ HVAC system integrators, pulp and paper mills, power and energy companies, etc. The configuration and installation options support facility retrofits as well as the most modern new construction requirements.
Configuration of the EPI Master-Touch Thermal Mass Flowmeter
The Master-Touch 9000MP Multipoint System includes one or more 9000MP probes and a 9600MP System Control Panel. The 9000MP flow transmitter probe assembly is the heart of the system. The probe assembly typically has two or more flow sensors mounted in a 1.5″ OD probe shaft. The 9000MP probe’s sensors are removable for field replacement in case of damage. Each sensor matches to its own bridge board and microprocessor to function, in effect, as a complete flow meter. The linearized output signals from the multiple sensor assemblies in each probe average to create one overall probe output signal.
The probe’s average output signal transmits to a Master-Touch 9600MP System Control Panel (SCP). If the installation contains more than one probe, the output signals from all the probes transmit to the SCP. Then, the SCP averages the values to create one system output. The System Control Panel is housed in a 12″ x 10″ NEMA 4X fiberglass enclosure. The SCP provides the power for the probe assemblies and receives the average outputs over a four-wire cable to each probe.
It also includes its own microprocessor assembly for system-level control and flow display. The SCP provides two analog output signals (0–5 VDC and 4–20 mA), as well as RS232 & RS485 Modbus RTU communications. The 4–20 mA grand average output can drive up to 1200 ohms.
Optional Air Purge System
The optional Air Purge System (APS) provides a means of cleaning the sensors in applications where particulates cause problems. Operators can externally control the frequency and duration of the purge cycle or by using the Master-Touch software. The system can also be set to maintain the flow rate at its level when the purge is active. This important option preserves the integrity of the flow rate and elapsed total data which might otherwise be compromised by the flow of the purge gas.
Thermal mass flow meters use the principle of convective heat transfer to directly measure mass flow. EPI’s proprietary thermal mass flow sensors use two ratiometrically-matched, reference-grade platinum Resistance Temperature Detectors (RTDs). A 316 Stainless Steel sheath encapsulates the platinum sensing element wire or, if necessary, a Hastelloy C sheath.
Our microcontroller smart sensor technology preferentially heats one RTD with the other RTD acting as the temperature reference. The process gas flow dissipates heat from the first RTD, causing an increase in the power necessary to maintain a balance between the RTDs. This increase directly relates to the gas molecular rate of flow. Our sensors feature temperature compensation for a wide process gas temperature range and insensitive to pressure changes, so the output signal is a true mass flow rate signal.