M-Th: 8AM-5PM

Fri: 7:30AM-3PM

M-Th: 8AM-5PM

Fri: 7:30AM-3PM

SmartMod, Modbus I/O with RS485 Half Duplex

SmartMod, Modbus I/O with RS485 Half Duplex

$264.00$703.00

Available on backorder

Featuring Modbus and a RS485 ½ duplex, SmartMod covers a variety of low cost input / output offerings, such as voltage, current, temperature, and digital. SmartMod I/O is a RTU/Modbus based input / output system designed to fill-out the input / output complement for applications utilizing XLe, LX, or any other OCS/RCS family Controller. As many as 31 SmartMod I/O modules may be daisy chained on a single RS-485 link. SmartMod I/O is DIN-rail mounted, powered from 10-30VDC, and features 2000vac optical isolation.

Description

SmartMod Configuration settings are mapped into Modbus Register space. This configuration data may be modified with any Modbus/RTU Master device. For convenience, Horner has developed a variety of Cscape application files, which allow a Horner OCS automation controller to act as a SmartMod configuration device. Initial configuration of SmartMod RS485 half duplex module should be done on an individual basis, since all modules come from the factory with a default Modbus ID of 1. Once each module on the network has its own unique Modbus ID, further configuration adjustments can be made with the entire network powered.

Common Uses of Horner I/O

SmartMod-io-input-output-plc-controller-moduleSmartMod Input / Output Model Line-Up

HE359DIQ512
4 DC Inputs (12/24VDC neg logic), 4 Relay Outputs (250vac, 30VDC, 2A max). 2000vac isolation (in-RS485 & in-power)
HE359ADC107
4 channel Analog Inputs, Voltage (+/-10VDC) 1mV resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359ADC120
4 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DIM610
12 DC Inputs (12/24VDC, neg logic). 2000vac isolation (in-RS485 & in-power)
HE359RTD100
4 channel RTD Inputs (Pt-100, Ni-100, Pt-1000, Ni-1000) or Resistance Inputs (0-2000ohm). 0.1 degree Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359THM100
4 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC007
2 channel Analog Outputs, selectable between Voltage (0-10VDC) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)
HE359ADC207
8 channel Analog Inputs, Voltage (+/-10VDC) 1mV resolution, 2000vac isolation (ch-RS-485 & ch-power)
HE359ADC220
8 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC107
4 channel Analog Outputs, selectable between Voltage (0-10VDC) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)
HE359THM200
8 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC201
8 channel Analog Outputs, Voltage (0-10VDC) 1mV resolution. 2000vac isolation (ch-RS485 & ch-power)