Kayden CLASSIC 800 Series, Switch and Transmitter

The CLASSIC 800 Series switch and transmitter offers threaded, flanged,  Tri-Clamp, and retractable packing gland process connection. It is user configurable for flow, level, fluids interface, temperature applications, and is suitable for use in air, gases, water, liquids, and slurries. Models in the Kayden CLASSIC 800 Series have several unique features that make them the world’s most advanced thermal flow and level switch including: temperature mode, 4-20 mA outputs, Modbus, digital temperature compensation, automated self-test diagnostics, and a simple, intuitive user interface.

The patented design of the CLASSIC 800 Series provides the ultimate performance and features package for flow, level, interface, and temperature sensing. It combines precision welded, highly accurate sensors, extremely rugged enclosures, and advanced digital electronics. In addition, these switches / transmitters offer failure resistance inherent in Thermal Dispersion technology with the performance and features usually reserved for much more expensive instrumentation.

Description

The CLASSIC 800 Series features switches and transmitters for flow, level, interface, and temperature process control. Each model has a precision welded, highly accurate stainless steel thermal sensor. The Kayden CLASSIC 800 Series is ideal for liquids, gases, and slurries in clean or dirty processes. Options for process connections include: raised face, RTJ flange, threaded, or retractable packing glands. In addition, all Kayden CLASSIC models feature a rugged flameproof enclosure with blind or lens cover options. Its advanced digital electronics will revolutionize the way you monitor and control your process.

  • easy setup; no jumpers or trim pots
  • continuous self-test diagnostics with fault indicator
  • temperature compensation
  • universal power 12-24 VDC and 115-230 VAC standard
  • two SPDT relays – independently adjustable
  • 4-20 mA analog output
  • smart heater function for power economy and increased heater life
  • start-up bypass timer (for pump control)

Kayden CLASSIC 800 Series Model Line Up

Kayden-CLASSIC-810-Threaded-Flow-Meter-Level-Switch-Interface-Temperature-Thermal-Sensor-Process-Solutions-Corp
CLASSIC 810 – Threaded
Kayden CLASSIC 810 – Threaded

Process Connections – MNPT

  • 1/2 inch, 3/4 inch, 1.0 inches, 1 1/4 inches, 1 1/2 inches, 2 inches

Approvals

  • FM
  • CSA
  • CRN
  • Single Seal
  • NACE
  • ASME BPVC Sec. VIII Div. 1
Kayden-CLASSIC-812-Flanged-Switch-and-Transmitter-Thermal-Sensor-Flow-Meter-Level-Switch-Interface-PSC-Texas
CLASSIC 812 – Flanged
Kayden CLASSIC 812 – Flanged

Process Connection

  • raised face, RTJ flange

Approvals

  • FM
  • CSA
  • CRN
  • Single Seal
  • NACE
  • NEMA 4X
Kayden-CLASSIC-814-Flanged-Retractable-Packing-Gland-Industrial-thermal-sensor-flow-meter-level-switch-interface-sensing-process-solutions-texas
CLASSIC 814 – Flanged Retractable Packing Gland
Kayden CLASSIC 814 – Flanged Retractable Packing Gland

Process Connection

  • retractable packing gland, raised face, or RTJ flange

Approvals

  • CSA
  • FM
  • Single Seal
  • NACE
  • NEMA 4X
Kayden-CLASSIC-816-Threaded-Retractable-Packing-Gland-Flow-Level-Interface-Switch-Temperature-Transmitter-Process-Solutions-Texas
CLASSIC 816 – Threaded Retractable Packing Gland
Kayden CLASSIC 816 – Threaded Retractable Packing Gland

Process Connection

  • threaded retractable packing gland (1″ MNPT)

Approvals

  • CSA
  • Single Seal
  • NACE
  • NEMA 4X
Kayden-CLASSIC-830-Threaded-In-Line-Flow-Meter-level-switch-interface-senor-process-solutions-corp
CLASSIC 830 – Threaded In-Line
Kayden CLASSIC 830 – In-Line Threaded

Process Connection

  • 3/4″ FNPT

Approvals

  • CSA
  • Single Seal
  • NACE
  • NEMA 4X
Kayden-CLASSIC-832-Flanged-In-Line-Flow-Switch-Level-gas-processing-Transmitter-Interface-Media-Process-Solutions-Corp
CLASSIC 832 – Flanged In-Line
Kayden CLASSIC 832 – In-Line Flanged

Process Connections

  • raised face, RTJ flange

Approvals

  • FM
  • CSA
  • Single Seal
  • NACE
  • NEMA 4X

Configuration Options for the Kayden CLASSIC 800 Series*

*options vary by model selection

Applications for the Kayden CLASSIC 800 Series
  • flow
  • level
  • interface
  • temperature
Process Connections
  • 3/4″ FNPT
  • flanged in-line
  •  MNPT
    • 1/2 inch
    • 3/4 inch
    • 1 inch
    • 1-1/4 inches
    • 1-1/2 inches
    • 2 inches
  • 1 to 3.5 inches Tri-Clamp
    • flanged
    • sanitary
  • retractable packing glands
    • threaded (1” MNPT)
    • flanged
Sanitary Tri-Clamp Style

Maximum Working Pressure

  • per flange rating
Flanged Style

Maximum Working Pressure

  • per flange rating
Insertion ‘U’ Lengths

Standard

  • 1.2 inches (3 cm)
  • 2 inches (5 cm)
  • 3 inches (7.5 cm)
  • 4 inches (10 cm)
  • 6 inches (15 cm)
  • 9 inches (23 cm)
  • 12 inches (30 cm)
  • 18 inches (45 cm)

Kayden CLASSIC 828 (Sanitary)

  • 2 inches (5 cm)
  • 3 inches (7.5 cm)
  • 4 inches (10 cm)
  • 6 inches (15 cm)

Custom Lengths

  • custom lengths available by 1/2″ (1 cm) increments
  • Kayden CLASSIC model dependent: minimum 1.2 inches (3 cm) to maximum 120 inches (305 cm)
Input Power Options

Universal Power Standard

  • 12-24 VDC
  • 115-230 VAC
  • 50-60 Hz

Consumption

  • maximum: 6.0 watts (fully configured)
Outputs
  • 4-20 mA current loop
  • two (2) independent SPDT sealed relay contacts
    • rated at 4 amps resistive 230 VAC or 30 VDC maximum
    • individually adjustable
Accuracy

Flow Service

  • ±1% set point velocity over operating range of ±50˚F (±28˚C)

Level Service

  • ±0.25 inches (±0.64 cm)
Response Time
  • approximately 0.5 to 30 seconds
Remote Electronics Options

Maximum Recommended Cable Length

  • 200 feet (60 meters)

Cable Type

  • 24 AWG minimum
  • twisted pairs
Heater Power
  • field adjustable to optimize performance
Start Up Bypass Timer
  • adjustable for 0 to 100 seconds
Communications
Operating Pressure (Maximum)

Maximum Working Pressure

  • 24 MPa (3500 psig) dependent on Kayden CLASSIC model and material of construction
Temperature Range (Sensor)

Continuous Service

Electronics

  • -67˚F to 149˚F (-55˚C to 65˚C)

Note: For temperatures above 149˚F (65˚C), electronics must be remotely mounted.

Storage

  • All Kayden CLASSIC models should be stored in a clean and dry environment between -34.5 to 140˚F (-30 to 60˚C).
Enclosure Material
  • copper-free aluminum (does not exceed 0.4% copper)
  • powder coated polyester TGIC (polyester triglycidyl isocyanurate)
  • NEMA 4 / Type 4 / IP55 rated
  • 1” FNPT conduit connection
  • buna o-ring on cover
Conduit Connection Cover
  • flameproof: blind cover or glass lens
Wetted Materials
Outputs and Communications for the Kayden CLASSIC 800 Series
  • two independent relays (SPDT)
  • 4-20 mA
  • Modbus
  • rated:
    • 120 Vac max
    • 30 Vdc max
    • 4A max
Switch Point Range, Insertion Style

Water-based Liquids

  • 0.01 to 3.0 feet/second (0.003 to 0.9 meters/second)

Hydrocarbon-based Liquids

  • 0.01 to 5.0 feet/second (0.003 to 1.5 meters/second)

Gases

  • 0.25 to 254 sfps (0.076 to 77 smps)
  • standard conditions: 70˚F (21˚C) at 14.7 psi (1 atm)
Switch Point Range, In-Line Models

Water-based Liquids

  • 0.015 to 50 cc/second

Hydrocarbon-based Liquids

  • 0.033 to 110 cc/second

Gases

  • 0.6 to 20,000 cc/second
  • standard conditions: 70˚F (21˚C ) at 14.7 psi (1 atm)
RCMS (Remote Control & Monitoring Software) Functions and Features
  • display panel lock-out
  • set points configuration*
  • relay actuation delay timer
  • independently configurable for both on and off / increasing or decreasing
  • adjustable from 0 to 5,000 seconds
  • start-up bypass timer*
  • adjustable from 0 to 100 seconds
  • relay mode configuration*
  • energized above or below set point
  • relay temperature mode configuration
  • heater power setting*
  • zero and span settings*
  • analog (4-20 mA) output configuration*
  • view and print graphing (trend) function
  • configuring settings; write to device, save to file, and print
  • fault event log

*also configurable from display panel

Weights and Dimensions
Warranty
  • one (1) year from shipment date from factory (see full Terms and Conditions for details)
Display Panel Indicators
  • relay 1 and 2
  • set point 1 and 2
  • fault alarm
  • run mode
  • start-up bypass timer (for pump control)
  • LED bar graph for flow rate, level, or interface indication
Configuration Mode Features
  • adjustable sensitivity
  • zero and span adjustment
  • Modbus addressable
Diagnostics
  • primary watchdog circuit monitors microprocessor parameter anomalies
  • secondary watchdog circuit monitors microprocessor health
  • heater monitored for out-of-range conditions
  • fault mode de-energizes relay(s) and halts power to the heater
Approvals and Certifications

CSA Approvals

  • ANSI/UL Class I, Div. 1, Groups B, C and D
  • Ex d IIB + H2
  • AEx d IIB+H2 (Class I, Zone 1, Group IIB + H2,) T3
  • Enclosure Type 4 / IP55 rated

Single Seal Approval

  • Per ANSI/ISA 12.27.01-2003

FM Approvals

  • Class I, Div. 1, Groups B, C and D
  • Class I, Zone 1, AEx d IIB+H2 T2D (Ta=75˚C) / T3 (Ta=65˚C)
  • Enclosure Type 4 / IP55 rated

CRN Canadian Registration Number

  • CRN approvals available
  • contact us for CRN information per model and jurisdiction

Kayden-CLASSIC-810-Rugged-Thermal-Sensor-In-Line-Flow-Meter-Level-Switch-and-Transmitter-Interface-Temperature-Flow-Switch-Pipeline-Gas-Processing-PSC-TexasApplications for the Kayden CLASSIC 800 Series

Flow
Level
  • storage tanks
  • oil separators and treaters – high, low, & interface level
  • sumps – all types of fluids ( water, oil, etc. )
  • free water knock-out tanks – high, low, and interface level
  • leak detection (accumulation reservoir)
  • tank overflow
  • sampler systems
  • sand separators
Interface
  • control in separation vessels
  • detection
  • control and level detection in settling vessels
Media
  • liquids, air, and gases
  • hazardous area and general-purpose areas
  • slurries
  • corrosive liquids

Process Conditions for this Switch / Transmitter for Flow, Level, Interface, and Temperature

Flow
Ideal Process Conditions Undesirable Process Conditions

Liquids

  • consistent process composition and temperature
  • sufficient straight run flow profile (minimizes turbulence)
  • recommended minimum of 5 pipe diameters from any disturbance

Air & Gas

  • consistent process composition and temperature
  • sufficient straight run flow profile (minimizes turbulence)
  • clean and dry

Slurries

  • consistent process composition and temperature
  • sufficient straight run flow profile (minimizes turbulence)

Emulsion

  • consistent process composition and temperature
  • sufficient straight run flow profile (minimizes turbulence)

Liquids

  • inconsistent process composition or temperature
  • insufficient straight run
  • turbulence
  • aerated fluids

Air & Gas

  • inconsistent process composition or temperature
  • wet or saturated air / gas

Slurries

  • inconsistent process composition or temperature
  • insufficient straight run
  • turbulence
  • aerated fluids

Emulsion

  • inconsistent process composition and temperature
  • insufficient straight run
  • turbulence
  • aerated fluids

Solids

  • dry, granulated processes are NOT good candidates for thermal switches
Level
Ideal Process Conditions Undesirable Process Conditions

Liquids

  • consistent process composition
  • non-turbulent

Slurries

  • consistent process composition

Emulsion

  • consistent process composition

Liquids

  • inconsistent process composition
  • turbulence
  • large temperature swings

Slurries

  • inconsistent process composition
  • turbulence
  • large temperature swings

Emulsion

  • inconsistent process composition
  • turbulence
  • large temperature swings

Solids

  • dry, granulated processes are NOT good candidates for thermal switches
Interface
Ideal Process Conditions Undesirable Process Conditions

Liquid to Liquid

  • consistent process composition and temperature
  • non-turbulent applications
  • large differential in thermal conductivities

Air or Gas to Liquid

  • consistent process composition and temperature
  • non-turbulent applications
  • dry gas

Emulsion

  • consistent process composition and temperature
  • large differential in thermal conductivities

Liquid to Liquid

  • inconsistent process composition or temperature
  • high aeration
  • high turbulence
  • small differential in thermal conductivities

Air or Gas to Liquid

  • inconsistent process composition or temperature
  • high turbulence

Emulsion

  • inconsistent process composition or temperature
  • high aeration
  • high turbulence
  • small differential in thermal conductivities

Solids

  • dry, granulated processes are NOT good candidates for thermal switches