DEHNgate SPD for Coaxial

DEHNgate SPD for Coaxial

$194.67$220.63

DEHNgate surge arresters (SPD) provide protection for coaxial systems such as large transmitters and receivers, modems, satellite systems, video and transmission systems, etc. They are universal surge and combined arresters, from DEHN, with maximum discharge capacity for coaxial systems. Their low voltage protection level is suitable for protecting terminal equipment and they offer extremely durable contact materials.

Additional modules are available that are not listed on this page. The products featured are in-stock in Houston and ready to ship. The DEHNgate series features a wide range of options that include:

  • 909710 – DGA BNC VCD
  • 929043 – DGA AG BNC
  • and much more…

Description

The arresters of the DEHNgate surge protection device (SPD) series, from DEHN, provide protection for coaxial systems such as satellite systems, modem technology, video and transmission systems, and large transmitters and receivers.

  • universal surge and combined arresters
  • maximum discharge capacity for coaxial systems
  • low voltage protection level also suitable for protecting terminal equipment
  • extremely durable contact materials

DEHNgate-surge-arrester-spd-for-coaxial-systems-process-solutions-corpDEHNgate SPD for Coaxial Systems

909710 – DGA BNC VCD

The space-saving surge arrester with BNC socket can mount on DIN rails for protecting video and camera systems. They are available with direct (VCD) or indirect shield connection (VCID), depending on the type, to avoid ground loops. This device is for ordinary indoor use on communication loop circuits, with isolation from the Public Switched Telephone Network. Checking for proper grounding continuity is necessary. Please install the protector in accordance with the applicable requirements of the National Electrical Code, Article 800 or other applicable local codes. The maximum circuit current for UL 497 B applications is limited to100 mA.

  • easily adaptable due to BNC sockets
  • available with direct or indirect shield earthing according to type
  • for installation in conformity with the lightning protection zone concept at the boundaries from 0B – 2 and higher
  • C2 Nominal Discharge Current (8/20 μs) Shield-PG (In): 10 kA
  • C2 Nominal Discharge Current (8/20 μs) Line-shield (In): 5 kA
  • Maximum Continuous Operating Voltage (DC) (UC): 6.4 V
929043 – DGA AG BNC

Surge arrester suitable for remote supply with exchangeable gas discharge tube. They offer long endurance due to minimum contact erosion resulting from the large-area contact surface of the gas discharge tube.

  • large-area contact surface for connecting gas discharge tubes
  • longevity due to minimum contact erosion at the inner conductor
  • for installation in conformity with the lightning protection zone concept at the boundaries from 0A – 1 and higher
  • C2 Nominal Discharge Current (8/20 μs) (In): 20 kA
  • Maximum Continuous Operating Voltage (DC) (UC): 180 V
  • D1 Lightning Impulse Current (10/350 μs) (Iimp): 5 kA