7 | Products by Manufacturer


Surge Protection

BLITZDUCTOR XT

BLITZDUCTOR XT

BLITZDUCTOR XT

Request Quote

Attach files by dropping them here or selecting one.
0%

BLITZDUCTOR XT

For more info: DEHN website

  • Combined lightning current and surge arrester

    • Maximum discharge capacity for two-pole, three-pole or four-pole interfaces
    • Capable of carrying lightning currents up to 10 kA (10/350 µs)
    • Low voltage protection level, capable of protecting terminal equipment

    With integrated LifeCheck monitoring

    • Arrester testing during operation
    • Detection of pre-damaged arresters
    • High signal availability thanks to preventive replacement of arresters

    SPD consists of a protection module and a base part

    • Vibration and shock-tested for safe operation
    • All protection components integrated in the protection module
    • Two universal base parts with / without signal disconnection
    • Minimum space requirements, 4 single lines or 2 pairs over a width of 12 mm

  • Download BLITZDUCTOR XT Data Sheet
BLITZDUCTOR XTU

BLITZDUCTOR XTU

BLITZDUCTOR XTU

Request Quote

Attach files by dropping them here or selecting one.
0%

BLITZDUCTOR XTU

For more info: DEHN website

  • Combined lightning current and surge arrester

    • Max. discharge capacity for balanced data interfaces
    • Capable of carrying lightning currents up to 10 kA (10/350 µs)
    • For installation in conformity with the lightning protection zone concept at the boundaries from 0A – 2 and higher

    With actiVsense technology

    • Automatically detects the signal voltage ranging from 0 to 180 V
    • Optimally adapts the voltage protection level to the currently applied signal
    • Capable of protecting terminal equipment due to adapted voltage protection level
    • One arrester type for two different data interfaces

    Integrated LifeCheck monitoring function

    • Arresters can be tested without downtime
    • Detection of pre-damaged arresters
    • High signal availability due to preventive replacement of arresters

    Arrester consists of a protection module and a base part

    • For DIN rail mounting with a standard base part
    • Easy replacement of protection modules
    • Vibration and shock-tested for safe operation
    • Two universal base parts with / without signal disconnection

  • Download BLITZDUCTOR XTU Data Sheet
HVI Conductor

HVI Conductor

HVI Conductor

Request Quote

Attach files by dropping them here or selecting one.
0%

HVI Conductor

For more info: DEHN website

  • High-voltage-resistant insulated down conductor for keeping the separation distance to electrically conductive parts according to IEC/EN 62305-3.

    • For use up to an equivalent separation distance s ≤ 75 cm (in air) or s ≤ 150 cm (solid material).
    • The HVI long Conductor meets the requirements according to EN 62561-1.
    • A processing temperature of ≥ 0 °C and a permanent temperature range (at fixed installation) of -30 up to +70 °C are to be minded.

  • Download DEHN HVI Conductor Specifications

Power Supply Systems

DEHNguard

DEHNguard

DEHNguard

Request Quote

Attach files by dropping them here or selecting one.
0%

DEHNguard

For more info: DEHN website

  • The single-pole devices of the DEHNguard S product family are characterized by their universal features. Be it as a single device or in combination with other devices – DEHNguard S surge arresters always provide adequate protection. The module release button and the approved "Thermo Dynamic Control" SPD monitoring device with dual tripping performance characterize the devices of the DEHNguard S series. As with all DEHNguard surge arresters, the user of DEHNguard S can rely on the dual "Thermo Dynamic Control" SPD monitoring device. It ensures a maximum degree of safety, even under harsh environmental conditions.

    Multi-purpose surge arrester consisting of a base part and plug-in protection module.

    High discharge capacity due to heavy-duty zinc oxide varistors (Imax 50 kA 8x20μs)

    • ANSI/UL 1449 – 3rd Ed. Recognized
    • High reliability due to "Thermo Dynamic Control" SPD monitoring device
    • Operating state/fault indication by indication flag in the inspection window
    • Easy replacement of protection modules without tools due to module locking system with module release button
    • The plug-in protection module can be replaced without the need to de-energize and without removing the distribution board cover

  • Download DEHNguard DG DG S 150 Data Sheet
    Download DEHNguard DG DG S 48 Data Sheet
    Download DEHNguard DG DG S 75 Data Sheet
Isolating Spark Gap

Isolating Spark Gap

Isolating Spark Gap

Request Quote

Attach files by dropping them here or selecting one.
0%

Isolating Spark Gap

For more info: DEHN website

Process Solutions Corp. Powering Productivity