ValuMass Flow Meters


Master-Touch Flow Meters

Standar Single Point - MP Series

Standar Single Point - MP Series

Standar Single Point - MP Series

Request Quote

Attach files by dropping them here or selecting one.
0%

Standar Single Point - MP Series

For more info: EPI website

  • The Master-Touch™ MP Series flow meters are available for both inline and insertion style installations. Most inline flow meters are available with a number of mounting options including MNPT or butt weld ends and ANSI, DN or JIS flanges. Smaller sizes are available with compression fittings or clamp flanges. All inline style flowmeters for line sizes of 3/4” and larger include a pair of inlet flow conditioners. These conditioners help to improve problematic, uneven flow profiles by disrupting the gas flow and allowing it to assume a more uniform profile, without adding any significant pressure drop in most applications. Insertion style flow meters can be installed with compression fittings, ball valve assemblies or flanges welded to the probe support. Tube flow sections, electropolishing and a certified "O2 cleaning" service are just some of the other options available to meet almost any installation requirement.

  • Download EPI Series 8000MP 8100MP
    Download EPI Series 8200MP
    Download EPI Series 8600MP 8700MP
    Download EPI Series 8800MP
Standar Single Point - MPNH Series

Standar Single Point - MPNH Series

Standar Single Point - MPNH Series

Request Quote

Attach files by dropping them here or selecting one.
0%

Standar Single Point - MPNH Series

For more info: EPI website

  • In the MPNH Series we have combined all of the features of our Master-Touch™ thermal mass flow meter technology with a convenient ABS enclosure. These enclosures have a clear polycarbonate cover for viewing the rate and total display. The cover can be easily removed for all input/output connections and for access to the 4-button keypad which provides direct control and adjustment of the flowmeter.

    Just like the Master-Touch™ MP Series, our MPNH Series flow monitors are available for both inline and insertion style installations. Most inline flow meters are available with a number of mounting options including MNPT or butt weld ends and ANSI, DN or JIS flanges. Smaller sizes are available with compression fittings or clamp flanges. All inline style flow meters for line sizes of 3/4” and larger include a pair of inlet flow conditioners. These conditioners help to improve problematic, uneven flow profiles by disrupting the gas flow and allowing it to assume a more uniform profile, without adding any significant pressure drop in most applications. Insertion style flow meters can be installed with compression fittings, ball valve assemblies or flanges welded to the probe support. Tube flow sections, electropolishing and a certified "O2 cleaning" service are just some of the other options available to meet almost any installation requirement. So you can have the accuracy and flexibility of the Master-Touch™ thermal mass flowmeter for virtually all non-hazardous applications.

    The Master-Touch™ MPNH Series gas flow monitor is approved by CSA/CUS for use in general purpose (Ordinary) area locations.

  • Download EPI Series 8000MPNH 8100MPNH
    Download EPI Series 8200MPNH
    Download EPI Series 8600MPNH 8700MPNH
    Download EPI Series 8800MPNH
Flow Averaging Tubes

Flow Averaging Tubes

Flow Averaging Tubes

Request Quote

Attach files by dropping them here or selecting one.
0%

Flow Averaging Tubes

For more info: EPI website

  • The Master-Touch™ FAT™ probes utilize a flow averaging tube to give a stable flow signal in applications where the flow profile is less than ideal, such as downstream of a bend, valve, tee or obstruction. The flow averaging tube has a number of large diameter (0.125”) inlet ports along the length of the upstream impact surface. The impact pressure at each inlet port is averaged inside the tube to create the axial flow through the tube and across our flow sensor. The gas flow then passes back into the main flow stream through the gas return ports located near the flow sensing elements.

    Anomalies in the actual flow profile or installations in non-circular ducts may require a C-Factor adjustment for the best accuracy. The velocity impact pressure follows a square root function. Therefore, the average velocity pressure in the FAT™ probe may vary slightly from the average of the velocities at each inlet port. The Master-Touch™ electronics easily accommodate the C-Factor adjustment.

    The FAT technology is available in the same range of physical configurations as the other Eldridge Products' instruments. Inline style averaging tubes are available for pipe sizes 2" and greater with flanged ends; insertion style FAT probes can be as small as 2" or as large as necessary (90+" to date!). Integral and remote electronics with approvals for hazardous or non-hazardous locations allow the FATs to meet most installation requirements.

    The Master-Touch™ MP Series Flow Averaging Tubes are approved by CSA/CUS, ATEX, IECEx and KOSHA for use in hazardous area locations.

    The Master-Touch™ MPNH Series Flow Averaging Tubes are approved by CSA/CUS for use in general purpose (Ordinary) area locations.

  • Download EPI Series 9100MP
    Download EPI Series 9100MPNH
    Download EPI Series 9200MP
    Download EPI Series 9200MPNH
    Download EPI Series 9700MP
    Download EPI Series 9700MPNH
    Download EPI Series 9800MP
    Download EPI Series 9800MPNH
Multipoint Systems

Multipoint Systems

Multipoint Systems

Request Quote

Attach files by dropping them here or selecting one.
0%

Multipoint Systems

For more info: EPI website

  • Each Series 9000MP Multipoint System includes at least one flow transmitter probe assembly and a Series 9600MP System Control Panel (SCP). The probe assembly is the heart of the multipoint system. The probe assembly consists of two or more flow sensors (maximum of 5 sensors per probe) mounted in a 1½" OD probe shaft. Each sensor is matched to its own microprocessor and is individually calibrated and linearized. The microprocessor for each sensor is mounted outside of the flow duct in an enclosure at the end of the probe shaft.

  • Download EPI Series 9000MP
    Download EPI Series 9000MP Manual

ValuMass Flow Meters

Series 400

Series 400

Series 400

Request Quote

Attach files by dropping them here or selecting one.
0%

Series 400

For more info: EPI website

  • The Series 400 ValuMass™ flowmeters include 16-bit linearization technology for excellent flow rate accuracy and rugged construction of 316/316L stainless steel wetted parts. The robust feature set includes:

    • a 0 – 5 or 0 – 10 VDC output
    • a 4 – 20mA output
    • RS485 Modbus RTU communications
    • a 0 – 1 kHz output proportional flow
    • an RS232C port
    • a 2-line, 16-character backlit LCD
    • a programmable dry contact Relay for alarms or pulsed output totalization

    ValuMass™ inline and insertion flowmeters accommodate virtually all installation requirements. The Series 400 inline style flow¬meters are available for line sizes from ¼” to 2”. The 3 ½” long flow sections have MNPT ends as standard for easy mounting in the process line. Other end fittings are available. The Series 440 insertion style flowmeters are available with 6”, 12” or 18” long probes which include a compression fitting. Other mounting options are available. ValuMass™ flowmeters accept 24VDC, 115VAC or 230VAC input power as specified at the time of purchase.

    The ValuMass™ Series 400 is CE compliant.

  • Download EPI Series 400
    Download EPI Series 400 Manual
Series 500

Series 500

Series 500

Request Quote

Attach files by dropping them here or selecting one.
0%

Series 500

For more info: EPI website

  • The Series 500 ValuMass™ flowmeters include 16-bit linearization technology for excellent flow rate accuracy and rugged construction of 316/316L stainless steel wetted parts. The robust feature set includes:

    • a 0 – 5 or 0 – 10 VDC output
    • a 4 – 20mA output
    • RS485 Modbus RTU communications
    • a 0 – 1 kHz output proportional flow
    • an RS232C port
    • a 2-line, 16-character backlit LCD and 4-button keypad
    • a programmable dry contact Relay for alarms or pulsed output totalization

    Our ValuMass™ inline and insertion style flow meters accommodate virtually all common installation requirements. The insertion style flow meters are available with ½” OD probes in 6”, 12” or 18” lengths and a compression fitting is included with all insertion style flowmeters. The inline style flow meters are available for line sizes from ¼” to 2”. The 3 ½” long flow sections have MNPT ends as standard for easy mounting in the process line. ValuMass™ flowmeters accept 24VDC, 115VAC or 230VAC input power as specified at the time of purchase.

    Now you can have the accuracy and reliability of an Eldridge Products' thermal mass flow meter for applications that don't require the full feature set of the Master-Touch™ product line.

    The ValuMass™ Series 500 is CE compliant.

  • Download EPI Series 500
    Download EPI Series 500 Manual